Slide background The HyDAF Dissolved Air Flotation (DAF) - Simplicity and Exceptional Performance
Click through to learn why the HyDAF is the Dissolved Air Flotation system of choice for industrial wastewater treatment today
Slide background Proudly Delivering Mining & Wastewater Clarifiers For Over 50 Years
Click through to learn about EPCO's range of clarifiers for mining processes and industrial wastewater.
Slide background MENA Water - MBR Packaged MBR Wastewater Treatment Systems - Deployable or Permanent Solution for Factory and Industrial Complex Wastewater
Slide background MENA Water - Packaged Drinking & Process Water Treatment Systems - Deployable or Permanent Solution for Factory's and Industrial Complexes
Slide background HydroThane - High Rate Anaerobic Reactors
Click through to learn more about how you can make energy from wastewater and generate 80% less sludge
Slide background FlooBed® MBBR Technology for Industrial Wastewater Biological Treatment
Click through to learn more about how this advanced system can save energy and space treating your wastewater.
Slide background The Neutralox Odour Control Systems for Wastewater
Click through to learn more about highly effective alternative odour control with lower capital costs and simple operation.

Wastewater BOD Testing – Is it Time for a Change?

The English water authorities more than 120 years ago realised that there are thousands of different organic molecules to test for and that testing for each one would be prohibitively expensive and time consuming, if not at that time, impossible.

BOD Chemicals

In response they devised the 5-day BOD test (BOD = biochemical oxygen demand). This test became a global standard as an indirect method to test the quantity of organic matter in water, and in fact it is still used today by many water authorities and governments worldwide.

The BOD test measures the quantity of dissolved oxygen needed by microorganisms to degrade organic compounds. The result is given as mg/L dissolved oxygen. The higher the organic load or strength of the water, the higher the quantity of dissolved oxygen required by the bacteria hence the higher the BOD result.

The 5-day BOD was a good test for the 19th century, especially as it was relatively low cost and simple to perform. Over time the acronym BOD almost became a standard word to describe organic contamination in water. For example, a water with a high BOD result was considered highly contaminated with organic matter; conversely a low BOD water was considered to be low in organic material. Unfortunately, this converse sentence may be quite incorrect, as a low BOD water may still be highly loaded with organics.

Of all the contaminants we test for, BOD is the least targeting and the least reproducible. A BOD result can be generated by thousands of different types of organic molecules, not just one or two different kinds. Hence the test gives us almost clues as to what actual organic molecule is in the water. Give the same sample to two laboratories and the chances of the results coming back the same are almost nil. Hence the results at best are only indicative of high, low or medium strength, and even this may be incorrect.

Apart from temperature and time being critical factors in the BOD test, the test is greatly affected by contaminant type and contaminant particle size, by the quality of the bacterial seed and by the matrix of the water sample – if for instance the water contains any slightly toxic compounds then the final BOD result will be artificially low. Conversely, samples with a high organic nitrogen component may give an artificially high BOD result.

As our understanding of water chemistry and biology increased since the inception of the 5-day BOD test, the inherently insurmountable shortcomings of this test are becoming more realised.

So what can we do to overcome or even replace the 5-day BOD test? The simple answer is a COD test (COD = chemical oxygen demand). While this test also has some shortcomings, and a handful of recalcitrant organic compounds (particularly those found in the petrochemical and coal industries) may not register properly during the test, it does accurately and reproducibly measure more than 95% of the oxidisable organic material found in almost any domestic or industrial waste stream.

The reliability and reproducibility of this low cost and a 2 hour turn around test is why COD is making an ever increasing mark on today’s modern wastewater analytical world.

About the Hydroflux Group
The Hydroflux Group comprises eleven companies based in Australia, New Zealand, the Pacific, and the UK, providing design and build, equipment, processes and operational services in water and wastewater treatment. Hydroflux Industrial specialises in industrial wastewater treatment including designing and constructing plants and supplying equipment across all sectors. Hydroflux Industrial is a member of the Hydroflux Group.